Analog Dry Block Heaters, Boekel Scientific

Supplier: BOEKEL INDUSTRIES

112004 112002 112001
Boekel Scientific Analog Dry Block Heaters are designed for a variety of applications, including restriction digests, C.O.D. denaturing DNA, BUN, melting agar, coagulation studies, in situ hybridization, and Hot Start PCR. These units provide an excellent value with a dynamic temperature range and rapid heat-up, making them ideal for virtually every application. The units are available in one, two, or four block capacity formats and accommodate a variety of Dry Block Modules for added flexibility.

The Single Block Heater features an Ambient +5° to 150 °C temperature range, while the Analog 2 Block and 4 Block models feature a temperature range of Ambient +5° to 130 °C

Boekel offers the complete spectrum of Dry Block Modules to accommodate microcentrifuge tubes, microplates, and test tubes up to 25 mm in diameter. Each precision machined solid aluminum block is anodized to resist corrosion and features alpha/numeric labeled rows and columns for simple vessel identification. Additionally, each Module features a well for a thermometer (not included) and a block extractor hole. They are interchangeable between the Analog and Digital Dry Block Heaters (see 35790-000 series).

All units offer a temperature uniformity of ± 0.50 at 37 °C. Also integrated into the quality design of these units is an over-temp safety feature providing safe heating of all samples.

Certifications: UL listed. CE certified. CSA approved.

Ordering information: Boekel Scientific Analog Dry Block Heaters are supplied with a block extractor for safe removal of the blocks, instruction manual, and power cord. Each unit comes with the Boekel two-year warranty on parts and labor. Dry Block Modules sold seperately.


 

ORDER

Expand All / Collapse All
Description Electrical Capacity Temperature Range Shipping Weight Supplier No. Catalog Number Unit List Price Quantity
Analog Dry Block Heater, One Block Capacity 115V, 50/60Hz, 100W 1 Dry Block Module Ambient +5° to 150°C 2.7 kg (6 lbs.) 112001 D-1100-1100 Each Retrieving
Analog Dry Block Heater, Two Block Capacity 115V, 50/60Hz, 100W 2 Dry Block Modules Ambient +5° to 130°C 2.7 kg (6 lbs.) 112002 D-1100-1200 Each Retrieving
Analog Dry Block Heater, Four Block Capacity 115V, 50/60Hz, 100W 4 Dry Block Modules Ambient +5° to 130°C 3.2 kg (7 lbs.) 112004 D-1100-1400 Each Retrieving

SPECIFICATIONS

Overall Dimensions 20.3W x 24.9L x 8.9H cm (8 x 9.8 x 3.5")
Temperature Uniformity ±0.50°C at 37°C

ACCESSORIES

Expand All / Collapse All

Accessories
Description For Use With Block Size Shipping Weight Supplier No. Catalog Number Unit List Price Quantity
Test Tube Block Module, 20 mm Tubes 6 x 20 mm Tubes 7.6W x 9.5L x 5H cm (3 x 33/4 x 2") 1 kg (2.25 lbs.) 110020 C-3105-6 Each Retrieving
Test Tube Block Module, 25 mm Tubes 6 x 25 mm Tubes 7.6W x 9.5L x 5H cm (3 x 33/4 x 2") 1 kg (2.25 lbs.) 110025 C-3105-7 Each Retrieving
Test Tube Block Module, 16 mm Tubes 12 x 16mm Tubes 7.6W x 9.5L x 5H cm (3 x 33/4 x 2") 1 kg (2.25 lbs.) 110016 C-3105-5 Each Retrieving
Test Tube Block Module, 10 mm Tubes 20 x 10 mm Tubes 7.6W x 9.5L x 5H cm (3 x 33/4 x 2") 1 kg (2.25 lbs.) 110010 C-3105-3 Each Retrieving
Test Tube Block Module, 13 mm Tubes 20 x 13 mm Tubes 7.6W x 9.5L x 5H cm (3 x 33/4x 2") 1 kg (2.25 lbs.) 110013 C-3105-4 Each Retrieving
Test Tube Block Module, 6 mm Tubes 35 x 6 mm Tubes 7.6W x 9.5L x 5H cm (3 x 33/4 x 2") 1 kg (2.25 lbs.) 110006 C-3105-2 Each Retrieving
Test Tube Block Module, 25 mm, 13 mm, and 6 mm Tubes 3 x 25 mm Tubes, 5 x 13 mm Tubes, 6 x 6 mm Tubes 7.6W x 9.5L x 5H cm (3 x 33/4 x 2") 1 kg (2.25 lbs.) 110035 C-3105-14 Each Retrieving
Test Tube Block Module, 1.5 mL Tubes 24 x 1.5 mL Tubes 7.6W x 9.5L x 5H cm (3 x 33/4 x 2") 1 kg (2.25 lbs.) 110040 C-3105-8 Each Retrieving
Test Tube Block Module, 0.5 mL Tubes 24 x 0.5 mL Tubes 7.6W x 9.5L x 5H cm (3 x 33/4 x 2") 1 kg (2.25 lbs.) 110045 C-3105-9 Each Retrieving
Microplate Block Module, 96-Well Microplate 1 x Standard 96-Well Microplate 9.5W x 13.3L x 4.4H cm (33/4 x 51/4 x 133/4") 1.4 kg (3 lbs.) 110051 C-3105-10 Each Retrieving
Misc. Block Module, 96-Well Microplate or 0.2 mL Strips or 0.2 mL Tubes 1 x Standard 96-Well Microplate, or 0.2 mL Strips, or 0.2 mL Tubes 9.5W x 15.2L x 2.5H cm (33/4 x 6 x 1") 1.4 kg (3 lbs.) 110096 D-1100-0700 Each Retrieving
Enter Certificate Details

Enter the Lot number:

Choose from recent batch/lot numbers:

Or
Review & Compare Alternatives
We found alternative products that can save you up to  per item-unit.  To compare product details, select up to 3 alternatives below and click Compare Selected.To add items to your basket, enter a quantity and click Add to Basket.

Original Product:

Description Catalog Number Availability Unit Your Price Price Per Qty
 

Terms & Conditions

Prices:
Prices shown are current at time of publication. Where changes have occurred, prices prevailing at the time of shipment will apply. Prices are subject to change without notice.

Quotations:
Our sales and customer service departments welcome quotations for laboratory set-ups and multiple-unit orders. Your inquiries are welcome and appreciated.

Payment Terms:
Payment terms are Net 30 Days on approved credit, F.O.B. warehouse or point of manufacture. Shipping charges are prepaid and added to the invoice. C.O.D. orders will be charged a $10.00 handling fee plus shipping charges. AMEX, MasterCard, and Visa are accepted.

Minimum Order:
There is no minimum order at BioExpress. Full case quantities or minimum quantities may apply to non-stock or specialty items.

DELIVERY & SHIPPING
All orders are shipped F.O.B. warehouse or point of manufacture. Shipping charges are prepaid and added to the invoice. Orders are usually shipped within 24 hours of receipt. We ship by the most efficient and economical means available. Extra charges apply to HAZMAT and dry ice shipments.

RETURN GOODS POLICY
If you would like to return an item, please call BioExpress customer service or contact your local representative for an RGA number. All returns must include an RGA number, include original packaging and be shipped prepaid. Items older than 30 days, sterile, or special order items are subject to review. A 15% restocking fee applies.

WARRANTIES AND LIABILITIES
BioExpress accepts no responsibility and shall not be held liable for loss, damage, expense, consequential, or accidental damage. This includes the damage to property, person, or premises resulting from these products. BioExpress MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURCHASE. BioExpress expressly disclaims all other warranties, whether express, implied or statutory, including the warranty of MERCHANTABILITY AND FITNESS FOR USE. In no event will BioExpress be liable for consequential damages arising from the use of products described in this catalog.

Print These Terms