Keep my session open?
Ending In 
The session is expired
Your session has expired. For your security, we have logged you out.
Would you like to log in again?

PYREX® ProCulture™ Spinner Flasks with Vertical Sidearms, Corning®

Supplier: CORNING CA

PYREX® ProCulture™
4512-8L 4510-36L 4512-36L 4510-15L 4514-36L 4512-15L 4514-15L 4510-8L
Borosilicate glass flasks are baffled to enhance agitation of contents.

Autoclavable sidearms fittings are available for gas delivery, media handling, and probe insertion. Gas delivery and media handling fittings enhance productivity of cell culture, while probe insertion fittings secure oxygen, temperature, or pH sensors in flasks to monitor cell culture parameters. All fittings operate as bioreactors when used together and attached to appropriate cell culture controllers. Fittings are comprised of PET insert with Viton® O-ring, stainless steel tubes held in place by Noryl® nuts with integrated ferrules, and 45 mm polypropylene sealing cap. Fitting 89090-016 features a high temperature resistant EPDM O-ring.

Gas venting cap filter has 0.2 µm pore PTFE membrane.

Dynamic vortex impellers ensure high performance stirring. Wide, vertical sidearms permit use with fittings and probes for feeding and harvesting of cells. May be used with direct drive motor or magnetically driven paddle assembly. Supplied with flat center screw caps.

Accessories information: Proculture® spinner direct top drive motor with high torque, low rpm specifically designed to maintain constant low speed for use on top of Proculture® spinner flasks. The gearhead stirrer motor delivers 14.5 in-lbs of torque and has a maximum speed of 350 rpm.
100 mm Center Cap Assembly for Proculture® Spinner Flasks is designed for use with direct overhead drive motor, these cap assemblies required optional 8L, 15 L or 36 L paddle assemblies.


 

ORDER

Expand All / Collapse All

Flasks with Four Vertical Sidearms
Capacity Center Neck O.D. Sidearm Neck O.D. Supplier No. Catalog Number Unit List Price Quantity
15 L 100 mm 45 mm 4510-15L F-4510-15L Case of 1 Retrieving
15 L 140 mm 45 mm 4514-15L F-4514-15L Case of 1 Retrieving
15 L 120 mm 45 mm 4512-15L F-4512-15L Case of 1 Retrieving
8 L 120 mm 45 mm 4512-8L F-4512-8L Case of 1 Retrieving
8 L 100 mm 45 mm 4510-8L F-4510-8L Case of 1 Retrieving

Flasks with Six Vertical Sidearms
Capacity Center Neck O.D. Sidearm Neck O.D. Supplier No. Catalog Number Unit List Price Quantity
36 L 120 mm 45 mm 4512-36L F-4512-36L Case of 1 Retrieving
36 L 140 mm 45 mm 4514-36L F-4514-36L Case of 1 Retrieving
36 L 100 mm 45 mm 4510-36L F-4510-36L Case of 1 Retrieving

ACCESSORIES

Expand All / Collapse All

Accessories
Description Fits Fits Flask Supplier No. Catalog Number Unit List Price Quantity
Corning® Proculture® Spinner Direct Top Drive Motor, 120 VAC 60 Hz, 4.1 Kg (9 lbs.) Corning® Proculture® Flasks - 400640 400640 Case of 1 Retrieving
Corning® Proculture® Spinner Direct Top Drive Motor, 230 VAC 50 Hz, 4.1 Kg (9 lbs.) Corning® Proculture® Flasks - 402645 402645-G Case of 1 Retrieving
Center Neck Cap Compression Fitting Assembly for Flasks with 0.3 cm (1/8") Tubing - 8 L and 15 L 4519-130 4519-130-G Case of 1 Retrieving
Center Neck Cap Compression Fitting Assembly for Flasks with 0.6 cm (1/4") Tubing - 8 L and 15 L 4519-134 4519-134-G Case of 1 Retrieving
Filtered Gas Venting Cap, 45 mm - - 4519-106 4519-106-G Case of 1 Retrieving
Filtered Gas Venting Cap with Sanitary Fitting, 50 mm - - 4519-177 4519-177-G Case of 1 Retrieving
Paddle Assemblies with Direct Drive Overhead Motor - 8 L 4515-8L 4515-8L-G Case of 1 Retrieving
Paddle Assemblies with Direct Drive Overhead Motor - 36 L 4515-36L 4515-36L-G Case of 1 Retrieving
Paddle Assemblies with Direct Drive Overhead Motor - 15 L 4515-15L 4515-15L-G Case of 1 Retrieving
ProCulture™ Fittings For Gas Delivery, with 0.3 cm (1/8") Inlet - - 4519-100 4519-100-G Case of 1 Retrieving
ProCulture™ Fittings For Gas Delivery, with 0.6 cm (1/4") Inlet - - 4519-102 4519-102-G Case of 1 Retrieving
ProCulture™ Fittings For Gas Delivery and Venting, with 0.3 cm (1/8") and 0.6 cm - - 4519-104 4519-104-G Case of 1 Retrieving
ProCulture™ Fittings For Media Handling, with 0.3 cm (1/8") and 0.6 cm (1/4") Inlets - 8 L or 15 L 4519-120 4519-120-G Case of 1 Retrieving
ProCulture™ Fittings For Media Handling, with 0.3 cm (1/8") and 0.6 cm (1/4") Inlets - 36 L 4519-122 4519-122-G Case of 1 Retrieving
ProCulture™ Fittings For Media Handling, with 1.3 cm (1/2") Inlet - 36 L 4519-126 4519-126-G Case of 1 Retrieving
ProCulture™ Fittings For Media Handling, with 1.3 cm (1/2") Inlet - 8 L or 15 L 4519-124 4519-124-G Case of 1 Retrieving
ProCulture™ Fittings For Media Handling, with Two 0.3 cm (1/8") Inlets - 8 L or 15 L 4519-112 4519-112-G Case of 1 Retrieving
ProCulture™ Fittings For Media Handling, with Two 0.3 cm (1/8") Inlets - 36 L 4519-114 4519-114-G Case of 1 Retrieving
ProCulture™ Fittings For Media Handling, with Two 0.6 (1/4") Inlets and High Temperature O-Ring - 8 L or 15 L 4519-176 4519-176-G Case of 1 Retrieving
ProCulture™ Fittings For Media Handling, with Two 0.6 cm (1/4") Inlets - 36 L 4519-118 4519-118-G Case of 1 Retrieving
ProCulture™ Fittings For Media Handling, with Two 0.6 cm (1/4") Inlets - 8 L or 15 L 4519-116 4519-116-G Case of 1 Retrieving
ProCulture™ Fittings For Oxygen, Temperature, or pH Probe Insertion, 18 mm (11/16") - - 4519-172 4519-172-G Case of 1 Retrieving
ProCulture™ Fittings For Oxygen Probe Insertion, 12 mm (1/2") - - 4519-108 4519-108-G Case of 1 Retrieving
ProCulture™ Fittings For pH Probe Insertion, 12 mm (1/2") - - 4519-110 4519-110-G Case of 1 Retrieving
ProCulture™ Fittings For Temperature Probe Insertion, 12 mm (1/2") - - 4519-128 4519-128-G Case of 1 Retrieving
Enter Certificate Details

Enter the Lot number:

Choose from recent batch/lot numbers:

Or
Review & Compare Alternatives
We found alternative products that can save you up to  per item-unit.  To compare product details, select up to 3 alternatives below and click Compare Selected.To add items to your basket, enter a quantity and click Add to Basket.

Original Product:

Description Catalog Number Availability Unit Your Price Price Per Qty
 

Terms & Conditions

Prices:
Prices shown are current at time of publication. Where changes have occurred, prices prevailing at the time of shipment will apply. Prices are subject to change without notice.

Quotations:
Our sales and customer service departments welcome quotations for laboratory set-ups and multiple-unit orders. Your inquiries are welcome and appreciated.

Payment Terms:
Payment terms are Net 30 Days on approved credit, F.O.B. warehouse or point of manufacture. Shipping charges are prepaid and added to the invoice. C.O.D. orders will be charged a $10.00 handling fee plus shipping charges. AMEX, MasterCard, and Visa are accepted.

Minimum Order:
There is no minimum order at BioExpress. Full case quantities or minimum quantities may apply to non-stock or specialty items.

DELIVERY & SHIPPING
All orders are shipped F.O.B. warehouse or point of manufacture. Shipping charges are prepaid and added to the invoice. Orders are usually shipped within 24 hours of receipt. We ship by the most efficient and economical means available. Extra charges apply to HAZMAT and dry ice shipments.

RETURN GOODS POLICY
If you would like to return an item, please call BioExpress customer service or contact your local representative for an RGA number. All returns must include an RGA number, include original packaging and be shipped prepaid. Items older than 30 days, sterile, or special order items are subject to review. A 15% restocking fee applies.

WARRANTIES AND LIABILITIES
BioExpress accepts no responsibility and shall not be held liable for loss, damage, expense, consequential, or accidental damage. This includes the damage to property, person, or premises resulting from these products. BioExpress MAKES NO WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING, WITHOUT LIMITATION, THE WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURCHASE. BioExpress expressly disclaims all other warranties, whether express, implied or statutory, including the warranty of MERCHANTABILITY AND FITNESS FOR USE. In no event will BioExpress be liable for consequential damages arising from the use of products described in this catalog.

Print These Terms